Didactum®
  Top » Catalog » RARITAN » POWER MANAGEMENT » RA-PX-5528
Categories
AKCP Monitoring Products (49)
AKCP securityProbe (15)
AKCP sensorProbe (30)
AKCP intelligent sensors (48)
AKCP temperatur sensors (7)
AKCP dry contact sensors (8)
AKCP motion detection (2)
AKCP security camera (3)
AKCP vibrationGlassBreak Sensor (1)
AKCp security sensor (4)
AKCP temp./hum. sensors (4)
AKCP voltage sensors (5)
AKCP water sensors (9)
AKCP other sensors (13)
AKCP Smoke Detector (1)
AKCess Pro Server (1)
AKCP Acces Control (17)
AKCP Accessories (14)
AKCP Spare-Parts (6)
AKCP IP video surveillance (3)
AKCP Warranty (13)
AKCP Bundle (11)
Modem for AKCP (3)
Signal Device / Monitoring (3)
Power Performance (3)
Guntermann & Drunck-> (22)
Grundig Security Systems-> (28)
Samsung Security-> (54)
Flir Thermal imaging cameras (25)
Arecont Vision (24)
TAMRON Lenses-> (27)
SECURITY-> (70)
IP Sockets (5)
AVOCENT->
KVM Drawer (5)
UPS-SYSTEMS-> (83)
RARITAN-> (76)
  PARAGON II Series (36)
  KVM OVER IP SWITCH (11)
  Accessories (14)
  POWER MANAGEMENT (9)
  KVM DRAWER (1)
  CENTRAL MANAGEMENT (2)
  MANAGEMENT BOARD (3)
Raritan Dominion PX-5528
Item Number: RA-PX-5528
Article weight: 10.80 kg
Manufacturer Number: PX-5528
Delivery Capacity:
I am interested in the product! 
 Free price request.
BOX_HEADING_CALL_ME_ALT
Raritan Dominion PX-5528

Raritan's Dominion® PX Intelligent Remote Power Management Solutions help IT administrators improve uptime and staff productivity, save money and improve utilization of power resources.

With the Dominion PX:

  • Emergencies can be resolved with remote serial and TCP/IP access to outlet-level switching, improving MTTR.
  • Capacity planning is simplified with unit-level and outlet-level power utilization information.
  • Staff can gather detailed power information to improve uptime and productivity.
  • Travel costs and time can be saved with remote power cycling and monitoring.

Information provided by the Raritan Dominion PX — displayed at the strip via an LED display, and remotely through a Web browser — can be used to improve capacity planning through power consumption information for both the PDU and individual receptacle. Precise, outlet-level access and control allows users to reboot attached devices.

Whether used alone or integrated with other Raritan solutions, the intelligent Dominion PX offers secure access with 256-bit AES encryption and strong passwords.  Dominion PX supports advanced authorization options including outlet-level permissions and LDAP/S, RADIUS and Active Directory®.  Flexible management interfaces support HTTP, HTTPS, IPMI, SMASH-CLP, SSH, Telnet and SNMP, as well as user-configurable, outlet-level delays for power sequencing.

Dominion PX Remote Power Management Solutions can be integrated with the following Raritan solutions:

  • KVM switches: Dominion® KX II and Paragon II
  • Secure console servers: Dominion SX
  • Centralized IT infrastructure management: CommandCenter® Secure Gateway
Highlights
  • Power Sequencing (User Defined)
    In the event the PX is reset, the outlets will be turned on in a user-defined sequence at user-defined intervals to prevent tripping circuit breakers due to in-rush currents. (Applies only to PX models that support switching.)
  • Receptacle Status Retention
    In the event of a power outage, power is restored only to those receptacles that were on before the outage. For PX models that don't support switching, power will be restored to all outlets.
  • Circuit Breakers
    The PX uses UL 489 circuit breakers instead of fuses in 30A/32A models or higher, meeting the newest safety standard for branch circuit protection (UL60950 third edition). This eliminates the need for spare fuses and the time to replace them. Also, in many cases, a certified/licensed electrician is required to replace a fuse, whereas circuit breakers can be reset by a user.
  • Power Monitoring
    Power Metering The PX enables users to measure power at the outlet level (RMS, apparent power), providing an accurate view of power consumption at both a server or PDU level.
  • Alerting
    In case a threshold is exceeded, or a circuit breaker trips, the PX alerts the user via e-mail, SMS (via external gateway), audio alarm, and SNMP TRAPs, providing advanced warning before major incidents occur.
  • Overload Alarm
    User-configurable current threshold provides audible and visual alarm on current overload, allowing the user to act immediately to prevent potential burnouts and interruption of services.
  • Environmental Monitoring
    The PX supports external optional but fully integrated temperature and humidity sensors, providing early warning about hotspots or changes in cooling.
  • Seven-Segment LED
    Display Shows actual current, voltage and circuit breaker status of the PDU for both the total strip and for individual receptacles.
  • IP Auto Configuration with DHCP, BOOTP
    Easy setup and administration.
  • Flexible Remote Access Options
    Users can access the PX through a variety of access protocols for switching (where supported), metering, data collection and monitoring:

    * Convenient HTML GUI
    * Server Management Interface (IPMI)
    * Network Management Interface (SNMP)
    * UNIX®-like console interface via serial connector or TELNET/SSH (compatible with SMASH server management)

  • Dynamic DNS Support
    Users can access the PX over a connection with a dynamically assigned IP address - which corresponds to a single DNS name.
  • IPMI and SMASH CLP
    The first and only PDU in the world that supports industry management standards: the Intelligent Platform Management Interface (IPMI) and the Distributed Management Task Force's (DMTF) Systems Management Architecture for Server Hardware (SMASH) CLP, providing a uniform way to manage both servers and the PDU.
Technical Data
  • Input

    • Voltage: 400V AC, three-phase WYE
    • Maximum amperage per phase: 32A
    • Frequency: 50-60 Hz
    • Plug type: IEC 60309

    Output

    • Voltage: 230V AC
    • Maximum amperage per circuit: 6 x 16A
    • Power: 22.2 kVA
    • Receptacles: 18 x IEC C-13, 6 x IEC C-19
    • Protection: 6 x 16A single pole magnetic UL489 circuit breakers

    Metering

    • Input: Current, voltage and power for each line
    • Output:
      • Current, voltage and power for each outlet and total PDU
      • Current and trip state (on/off) for each circuit breaker

    Interface and Protocol Support

    • 10-100 Mbps Ethernet (RJ-45 connector)
    • RS-232 serial (RJ-45 connector)
    • SNMPv2, v3 TRAPs, GETs, SETs
    • Web browser and command line interface access

    Mechanical

    • Rack space: Zero U
    • Mounting: Rack mount brackets included
    • Dimensions (WxDxH): 2.06" x 2.57" x 70.08"; 52 x 65 x 1780mm
    • Weight: 23.8 lbs; 10.8 kg
    • Display panel: LED for PDU and outlet current and voltage
    • Line cord: 10 ft / 3 m

    Environmental requirements

    • Operating temperature: 5-45 degrees Celsius
    • Humidity: 5-90% RH non-condensing
    • Altitude: 10,000 feet

    Approvals

    • FCC Part 15, A; UL and c-UL 60950
    • RoHS compliant

    Warranty

    • Two years
Delivery:
  • Raritan Dominion PX-5528
Back
Manufacturer Info
Raritan Homepage
Other products
Tell A Friend
 
Tell someone you know about this product.
Quick Find
 
Use keywords to find the product you are looking for.
Advanced Search
Information
Shipping & Returns
Privacy Notice
Terms and Conditions
Didactum® retailer
Training & Workshops
Our services
Battery regulation
About Didactum®
Safe Shopping
Contact Us
Imprint
Languages
English Deutsch Französisch Spanisch Russisch Italian Portugues

Copyright © 2012 Didactum®
Please understand that Didactum ® exclusively commercial customers, companies and public institutions and authorities supplies.
Corporate customers and public institutions (public authorities, municipalities, universities, etc.) are Didactum ® on behalf of supplies (credit test).
Please tell us your VAT.
All prizes are presented in euros and do not include value added tax (VAT) and postage.